Eliminate dross formation

The LMPA-Q does not need nitrogen for wave soldering. Due to its low oxydation behaviour, dross formation is reduced to an absolute minimum.

SAC 305 dross after 7 production shifts ≈ 7kg

dross formation SAC

LMPA dross after 7 production shifts ≈ 0.4kg

dross formation LMPA